• Skip to primary navigation
  • Skip to main content
  • Skip to footer
C2C Power Solutions Logo

C2C Power Solutions

Show Search | 877.838.1088

It works. every time.

Search

Hide Search
  • Load Banks
    • Resistive Reactive Load Banks
      • Overview
      • 500 kVA
      • 3500 MVLB
      • 3500 MVLB Trailer
      • 1.875 MVA
      • 3.3 MVA
      • 6.25 MVA
    • Medium-Voltage Load Banks
      • Overview
      • 3500 MVLB
      • 3500 MLVB Trailer
    • Resistive Load Banks
      • Overview
      • 700 kW
      • 1.25 MV
      • 2 MV
      • 3.5 MV
      • 250kW Hybrid Rack
      • 500 kW Liquid Cooled
    • Liquid Cooled Load Banks
      • Overview
      • 250kW Hybrid Rack
      • 500 kW Liquid Cooled
  • Transformers
  • Sales
  • Rentals
  • Data Centers
    • Overview
    • Data Center Solutions
    • Liquid Cooled Load Banks
    • FAQs
  • Parts & Service
  • Support
  • Pre-Owned Inventory
  • Contact
  • Show Search

Industry Focus: Data Center Solutions

Total Facility Validation from the Utility Feed to the AI Rack.

In a mission-critical environment, your infrastructure is only as reliable as its most recent stress test. Load bank testing provides essential validation across the entire power chain. For example, it confirms that standby generators and UPS systems transition smoothly during a utility failure. It also verifies that the cooling plant can reject heat loads at full capacity.

By simulating the electrical and thermal demands of traditional enterprise servers and high-density AI clusters, our solutions uncover hidden vulnerabilities before they lead to costly outages. Furthermore, whether commissioning a new build or performing routine maintenance, we deliver the empirical proof that backup systems and cooling loops will perform when they are needed most.

The Exterior Power Plant

Medium Voltage Commissioning
Direct connect medium voltage load banks are provided to support commissioning up to 33 kV. As a result, substations and high voltage distribution loops can be tested directly. This allows the primary utility connection to be commissioned without the added complexity of multiple step down transformers.

Hyperscale Generator Testing
The fleet includes large 6.25 MVA resistive reactive containers designed to test generator sets under realistic operating conditions. These units allow testing at a true 0.8 power factor. Therefore, alternators and voltage regulators perform correctly under real world electromagnetic loads.

All Weather Reliability
Generator yards operate outdoors and must perform in all conditions. These units feature IP55 rated enclosures and stainless steel elements designed to operate reliably in extreme environments. For instance, they function well from desert conditions to Antarctic climates.

3500 MLVB Load Bank
3500 MLVB Load Bank Trailer

The White Space

Air Cooled Testing
Portable resistive load banks ranging from 100 kW to 500 kW are used to emulate the resistive heat load generated by server racks. When placed in hot aisles, these units generate precise heat loads that allow cooling infrastructure to be tested under realistic conditions. As a result, airflow dynamics, hot and cold aisle containment, and overall HVAC performance can be validated. This also stress tests the power ecosystem to ensure it can deliver the high density power required to operate IT infrastructure reliably.

High Density Liquid Cooled Testing
Water cooled load banks rated at 500 kW connect directly to coolant distribution units to verify flow rates, pressure drops, and heat rejection capacity within the primary cooling loop. Meanwhile, hybrid rack validation is supported through a single chassis design that integrates 100 kW of air cooling and 150 kW of liquid cooling. This approach allows modern AI racks that rely on liquid cooling for GPUs and air cooling for switches to be tested simultaneously. For sensitive direct to chip environments, stainless steel wetted components ensure zero contamination enters the cooling system. Therefore, loop integrity and long term performance are protected.

250 kW Hybrid Load Bank
500 kW Liquid Cooled Load Bank

Critical Power Systems

Backup power systems must be mission ready before a facility goes live. Resistive and resistive reactive load banks are deployed to simulate realistic electrical loads and lagging power conditions. This ensures generators and upstream power systems perform as required under real operating scenarios

Battery autonomy testing is supported through specialized DC load banks that validate battery systems and backup power sources against required discharge times. In addition, resistive load banks are used for UPS burn in testing. This process allows steady state heat runs to verify efficiency and thermal stability before systems are placed into service.

Resistive Reactive Load Banks
Resistive Load Banks

One Partner Advantage

Why manage four vendors for one facility? C2C Power Solutions simplifies your supply chain by delivering the entire commissioning package through a single partner. In fact, we go beyond providing a load bank by supplying the transformers, trailers, and cables needed to connect the full system. Additionally, site walks ensure the right solution is delivered. So when testing begins, you can be confident your partner has your back.

From operator-free rentals where equipment is delivered to your site, to full-service execution with technicians handling setup and teardown, we adapt to your project’s labor needs. With one call, you get total validation. Whether you are testing a 33 kV substation, backup power, or an AI rack, C2C Power Solutions has the inventory and expertise to help commission your entire data center.

Let’s Connect

Partner with C2C Power Solutions Today

Choose C2C Power Solutions for the best selection of load banks—backed by industry-leading warranties, fast delivery, expert support, and a full rental fleet. Whether you’re looking to buy or rent, our team is here to help you find the perfect solution.

Request Call

Footer

C2C Power Solutions

C2C Power Solutions is the leading authorized distributor of Crestchic® load banks and a premier dealer of Vantran® transformers.

Whether you’re looking to buy or rent load banks, C2C Power Solutions offers new and used resistive, reactive, and medium-voltage load banks, transformers, trailers, and cables—all backed by our commitment to value and service.

Hot Links

  • In-the-Know
  • Special Offers
  • Request Call
  • Rental Request
  • Order Parts
  • Service Request
  • Support
  • Training
  • Careers
  • Press
  • About

Contact Us

C2C Power Solutions
16945 Camino San Bernardo
San Diego, CA 92127
877.838.1088
[email protected]

  • Instagram
  • Facebook
  • LinkedIn

Copyright © 2026 · C2C Power Solutions

  • Terms
  • Privacy Statement
  • Site Map
  • Accessibility Statement
  • Powered by Parallel
^